Self-adaptive Coordinated Signal Controller
Product Overview
GJK-8 centralized coordinated road traffic signal controller adopts industrial control modular design. It is sturdy, durable, anti-corrosive, waterproof and dustproof. Embedded real-time multitasking operation system researched and developed independently makes the controller safer and more stable.The controller conforms to Standard GB25280-2016“Road Traffic Signal Controller” . At the same time, the directives and message formats(communication protocols) are in compliance with the requirements of Standard GB25280-2016“Road Traffic Signal Controller”Annex A.
Features
l Class C Grade A centralized coordinated traffic signal controller,19 inches 4U standard rack-mounted design;
l Support custom-made imaging guard duty manual control panels, wireless manual control panels and pedestrian crossing buttons;
l Three control models, “Holidays and Festivals”, “Week” and “General”;
l Can set 48 periods and support 255 control schemes such as multi-period fixed cycle control, inductive control, tidal flow lane(reversible lane) control, pedestrian crossing request control, single-point self-adaptive control, trunk line self-adaptive coordinated control, exit congestion control, event detection control, multi-lane merging self-adaptive control, yellow flashing control,full red control, lights out control and so on;
l Support countdown control under inductive and self-adaptive control;
l Support non-communication mode and RS485 communication mode controlling the countdown timer;
l Support learning countdown which can be closed in advance or immediately under non-communication mode;
l Support front-end virtual detector setting (including time, flow, occupancy, internet data of the third party);
l Support simple logical operation;
l Possessing industrial visual touching terminal interface; Linked to the terminal, the controller parameters can be directly displayed,checked and viewed, and even modified.
l There is yellow flash control device in the controller, which is independent of lamp driving output circuit.
l The controller can automatically record the breakdowns and keep operating in degraded situation when breakdowns happen, such as lights breakdown, communication failure, detector malfunction and so on.
Model Number
XHJ-CW-GA-GJK-8
Technical Parameters
Processor | 32 Industrial Grade ARM Processor |
Phase Quantity | 16 Phase(Standard), 20/24/32 Phase (Optional) |
Signal Light Output | 16 Independent Signals Output(Standard), 20/24/32 Independent Signals Output(Optional) |
User Interaction | Industrial Visual Touching Terminal(Standard) |
Detection Input Quantity | 32(Standard), 64(Optional) |
Detection Input Type | Loop, Geomagnetic, Video, Micro Wave and RFID |
Internet | One 100M Self-adaption RJ45 |
Data Input/Output | Two RS-232, Two RS-485, One USB, WIFI |
External Input | 8 Pedestrian Crossing Buttons |
Overall Power Consumption | <50W |
Insulation Strength | >50MΩ |
Driving Power | Single Group Output Power ≤800W |
Working Voltage | AC176V-264V,50Hz±2Hz |
Standby Power Interface | Built-in 220V Power Socket |
Switching Mode between Main Power and Standby Power | Manual |
Withstanding Voltage
| Exerting 1500V 50 Hz Voltage between accessible parts for 60s, there is no punch-through. |
Leakage Current | <5mA |
Electromagnetic Immunity(EMI) | Electrical accidents are not existing in all kinds of electromagnetic disturbance environments such as electrostatic discharge,fast transient pulse group, surge, voltage short break and so on. |
Working Temperature | -40~+70℃ |
Working Humidity | <95%@40℃, No Condensation |
Water Resistance | After rainfall test, there is no water seepage or water accumulation phenomenon in the cabinet. |
Dust Resistance | In and after dust test, the controller can work normally and there is no a lot of dust in the cabinet. |
Corrosion Resistance | After salt spray test, the controller can work normally and there is no serous corrosion on metal parts such as the cabinet and the internal racks. |
Lightning- protection Level | Grade Ⅱ |
Outer Cabinet Dimensions | 600*600*1400mm |
Cabinet Material | Stainless Steel Spraying Plastic, Thickness≥2.0mm, Opening Angle of the Door >120° |
Weight | 118(KG) |
Installation Method | Floor Type Cabinet Installation |
Dimensions
Self-adaptive Coordinated Signal Controller
Product Overview
GJK-8 centralized coordinated road traffic signal controller adopts industrial control modular design. It is sturdy, durable, anti-corrosive, waterproof and dustproof. Embedded real-time multitasking operation system researched and developed independently makes the controller safer and more stable.The controller conforms to Standard GB25280-2016“Road Traffic Signal Controller” . At the same time, the directives and message formats(communication protocols) are in compliance with the requirements of Standard GB25280-2016“Road Traffic Signal Controller”Annex A.
Features
l Class C Grade A centralized coordinated traffic signal controller,19 inches 4U standard rack-mounted design;
l Support custom-made imaging guard duty manual control panels, wireless manual control panels and pedestrian crossing buttons;
l Three control models, “Holidays and Festivals”, “Week” and “General”;
l Can set 48 periods and support 255 control schemes such as multi-period fixed cycle control, inductive control, tidal flow lane(reversible lane) control, pedestrian crossing request control, single-point self-adaptive control, trunk line self-adaptive coordinated control, exit congestion control, event detection control, multi-lane merging self-adaptive control, yellow flashing control,full red control, lights out control and so on;
l Support countdown control under inductive and self-adaptive control;
l Support non-communication mode and RS485 communication mode controlling the countdown timer;
l Support learning countdown which can be closed in advance or immediately under non-communication mode;
l Support front-end virtual detector setting (including time, flow, occupancy, internet data of the third party);
l Support simple logical operation;
l Possessing industrial visual touching terminal interface; Linked to the terminal, the controller parameters can be directly displayed,checked and viewed, and even modified.
l There is yellow flash control device in the controller, which is independent of lamp driving output circuit.
l The controller can automatically record the breakdowns and keep operating in degraded situation when breakdowns happen, such as lights breakdown, communication failure, detector malfunction and so on.
Model Number
XHJ-CW-GA-GJK-8
Technical Parameters
Processor | 32 Industrial Grade ARM Processor |
Phase Quantity | 16 Phase(Standard), 20/24/32 Phase (Optional) |
Signal Light Output | 16 Independent Signals Output(Standard), 20/24/32 Independent Signals Output(Optional) |
User Interaction | Industrial Visual Touching Terminal(Standard) |
Detection Input Quantity | 32(Standard), 64(Optional) |
Detection Input Type | Loop, Geomagnetic, Video, Micro Wave and RFID |
Internet | One 100M Self-adaption RJ45 |
Data Input/Output | Two RS-232, Two RS-485, One USB, WIFI |
External Input | 8 Pedestrian Crossing Buttons |
Overall Power Consumption | <50W |
Insulation Strength | >50MΩ |
Driving Power | Single Group Output Power ≤800W |
Working Voltage | AC176V-264V,50Hz±2Hz |
Standby Power Interface | Built-in 220V Power Socket |
Switching Mode between Main Power and Standby Power | Manual |
Withstanding Voltage
| Exerting 1500V 50 Hz Voltage between accessible parts for 60s, there is no punch-through. |
Leakage Current | <5mA |
Electromagnetic Immunity(EMI) | Electrical accidents are not existing in all kinds of electromagnetic disturbance environments such as electrostatic discharge,fast transient pulse group, surge, voltage short break and so on. |
Working Temperature | -40~+70℃ |
Working Humidity | <95%@40℃, No Condensation |
Water Resistance | After rainfall test, there is no water seepage or water accumulation phenomenon in the cabinet. |
Dust Resistance | In and after dust test, the controller can work normally and there is no a lot of dust in the cabinet. |
Corrosion Resistance | After salt spray test, the controller can work normally and there is no serous corrosion on metal parts such as the cabinet and the internal racks. |
Lightning- protection Level | Grade Ⅱ |
Outer Cabinet Dimensions | 600*600*1400mm |
Cabinet Material | Stainless Steel Spraying Plastic, Thickness≥2.0mm, Opening Angle of the Door >120° |
Weight | 118(KG) |
Installation Method | Floor Type Cabinet Installation |
Dimensions